                  Gold-life micropump development and production center

                  Homepage
                  Favorite

                  | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

                  Select micro-pump

                  pressure unit conversion table

                  GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  (mA)

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  (mL/min)

                  Weight

                  (g)

                  Pump Size

                  Detailed Structure of the show

                  reference Appearance

                  GminiPA-1

                  3.5

                  30-50

                  35

                  -25

                  800

                  16

                  162431

                  >>here

                  GminiPA-2

                  3.5

                  30-40

                  35

                  -20

                  300

                  16

                  162431

                  >>here

                  Ibid

                  pressure unit conversion table

                  GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  (mA)

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  (mL/min)

                  Weight

                  (g)

                  Pump Size

                  Installation instructions

                  Detailed Structure of the show

                  reference Appearance

                  GminiPB-1

                  3.5

                  100

                  35

                  -25

                  800

                  28

                  162441

                  >>here

                  GminiPB-2

                  3.5

                  100

                  35

                  -20

                  300

                  28

                  162441

                  >>here

                  Ibid

                  GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  (mA)

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  (L/min)

                  Weight

                  (g)

                  Pump Size

                  Installation instructions

                  Structure of the show

                  reference Figure

                  GMPA-1

                  1.5-5

                  test:4V

                  40-100

                  50

                  20-30

                  0.3-1.5

                  35

                  402336

                  flow-load diagram

                  voltage-flow chart

                  Structure>>here

                  GMPA-2

                  2.0-5

                  test:4V

                  30-100

                  50

                  30-40

                  0.5-2.0

                  35

                  402336

                  Ibid

                  Ibid

                  GMPA-3

                  3-6

                  40-70

                  50

                  20-30

                  0.5-1.5

                  35

                  402336

                  Ibid

                  Ibid

                  GMPA-4

                  3-6

                  50-90

                  50

                  30-40

                  0.5-1.8

                  35

                  402336

                  Ibid

                  Ibid

                  GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  (mA)

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  (L/min)

                  Weight

                  (g)

                  Pump Size

                  Installation instructions

                  Structure of the show

                  reference Figure

                  GMPC-1/2/3

                  6/9/12

                  <200/120/90

                  >100

                  50-65

                  2.5-3

                  45

                  502231

                  Structure>>here

                  flow-load diagram

                  voltage-flow chart

                  GMPC-4/5/6

                  6/9/12

                  <150/110/80

                  >80

                  50-55

                  2.0-2.5

                  45

                  502231 ibid

                  ibid

                  GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  (mA)

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  (L/min)

                  Weight

                  (g)

                  Pump Size

                  Installation instructions

                  Structure of the show

                  reference Figure

                  GMPD-1/2/3

                  6/12/24

                  <230/130/80

                  60-100

                  60

                  3-8

                  82

                  3544.556.5

                  flow-load diagram

                  voltage-flow chart

                  Structure>>here

                  GMPD-4/5/6

                  6/12/24

                  <200/100/60

                  60-100

                  50

                  3-7

                  82

                  3544.556.5 ibid

                  ibid

                  Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

                  GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  mA

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GMPE-1/2

                  12/24

                  <180/90

                  60

                  50-55

                  3-6

                  149

                  33543.572

                  flow-load diagram

                  voltage-flow chart

                  Structure>>here

                  GMPE-3/4/-

                  12/24 -20-40 Custom 3L4L5L 149 3543.572

                  Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

                  GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  A

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GMPF25-1/2

                  12/24 0.6/.3 >100 -70 25 480 8656.5126

                  Structure>>here

                  GMPF15-3/4

                  12/24 0.6/0.3 >60 -50 18 480 8656.5126

                  Structure>>here

                  GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  A

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GMPG-1/2

                  6-12/24

                  <0.450

                  100

                  20-50

                  36

                  620

                  8670126

                  Structure>>here

                  GMPG-3/4

                  6-9/24

                  <0.550

                  100

                  20-50

                  36

                  620

                  8670126

                  ibid

                  GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  A

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GDMPB-1/2

                  6/12

                  <0.25/0.135

                  100

                  series260

                  -45-55

                  series vacum

                   -85

                  single:22

                  dual:2.8

                  55

                  244749

                  flow-load diagram

                  voltage-flow chart

                  Structure>>here

                  GDMPB-3/4

                  6/12

                  <0.25/0.135

                  100

                  series260

                  50-65

                  single:2.52

                  dual:3.8

                  55

                  244749

                  ibid

                  GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  A

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GDMPC-1/2

                  12/24

                  <0.135/0.08

                  100

                  series260

                  -45-55

                  series vacum

                  -75

                  single

                  22L/min

                  dual

                  2.8L/min

                  75

                  244751

                  flow-load diagram

                  voltage-flow chart

                  Structure>>here

                  GDMPC-3/4

                  12/24

                  <0.135/0.08

                  series

                  260

                  -50-65

                  series vacum

                  -80

                  single:2.52

                  dual:3.8

                  5

                  244751

                  ibid

                  GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  mA

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GDMPD-1/2

                  12/24

                  <200

                  /135

                  100

                  -40-50

                  series vacum

                  -75

                  single:72

                  dual:10

                  107

                  354855.5

                  GDMPD-3/4

                  12/24

                  <240

                  /135

                  100

                  -40-60

                  series vacum

                  -80

                  single:82

                  dual:11

                  107

                  354855.5

                  GDMPD-5/6

                  12/24

                  <180

                  /115

                  100

                  -35-45

                  single:52

                  dual:8

                  107

                  354855.5

                  GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  mA

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GDMPE-1/2

                  12/24

                  <180/100

                  100

                  -40-50

                  series vacum

                  -75

                  single:62

                  dual:10

                  175

                  354871.5

                  flow-load diagram

                  voltage-flow chart

                  Structure>>here

                  GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  A

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GDMPF(40)-1/2

                  12/24

                  0.80

                  100

                  20-60

                  single:282

                  dual:40

                  618

                  1056.5126

                  voltage-flow chart

                  Structure>>here

                  GDMPF(25)-3/4

                  12/24

                  0.70

                  100

                  20-60

                  single:202,

                  dual:25

                  663

                  1056.5126

                  ibid

                  GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  A

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GDMPG(50)-1/2

                  6-12/24

                  <1.0

                  60

                  20-50

                  single:352

                  dual:50

                  759

                  11070126

                  Structure>>here

                  GDMPG(35)-3/4

                  6-12/24

                  <1.0

                  -50-60

                  20-50

                  single:252

                  dual:50

                  759

                  11070126

                  Structure>>here

                  GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  A

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 4564.5124

                  Structure>>here

                  GFMPE-3/4

                  12/24

                  <0.67/0.35.67

                  --

                  45

                  Four:3-15

                  375 4564.5124
                  Other Four:1-10 375 4564.5124

                  HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

                  Name and model

                  Voltage

                  (V)

                  No-load Current

                  mA

                  Pressure

                  (kPa)

                  Vacum

                  (kPa)

                  Intake Flow

                  L/min

                  Weight(g)

                  Pump Size

                  Structure of the show

                  reference Figure

                  HLA-2

                  --

                  50mL and 100mL two tranches.

                  Help

                  Categories

                   

                                             Return Home Page